| データシートサーチシステム |
|
L6759D データシート(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6759D データシート(HTML) 42 Page - STMicroelectronics |
|
42 / 51 page ![]() PMBus support L6759D 42/51 Doc ID 023240 Rev 1 12 PMBus support The L6759D is compatible with PMBus™ standard revision 1.1, refer to PMBus standard documentation for further information (www.pmbus.org). Table 11. Supported commands Command Per rail Code [Hex] Mode Comments OPERATION Y 01 RW byte Used to turn the controller on/off in conjunction with the input from the control pin. Also used to set margin voltages. Soft-off not supported ON_OFF_CONFIG N1 02 RW byte Configures how the controller responds when power is applied. WRITE_PROTECT Y 10 RW byte Controls writing to the PMBus device to prevent accidental changes. VOUT_COMMAND Y 21 RW word Causes the converter to set it's output voltage to the commanded value - VID mode. VOUT_MAX Y 24 RW word Sets the upper limit on the output voltage regardless of any other command VOUT_MARGIN_HIGH Y 25 RW word Sets the voltage to which the output is to be changed when the OPERATION command is set to “Margin High” VOUT_MARGIN_LOW Y 26 RW word Sets the voltage to which the output is to be changed when the OPERATION command is set to “Margin Low” IOUT_CAL_OFFSET Y 39 RW word Calibration for IOUT reading. OT_FAULT_LIMIT Y 4F RW word Overtemperature fault threshold. OT_WARN_LIMIT Y 51 RW word Overtemperature warning threshold. VIN_OV_FAULT_LIMIT N 55 RW word Input voltage monitor overvoltage limit. VIN_UV_FAULT_LIMIT N 59 RW word Input voltage monitor undervoltage limit. MFR_SPECIFIC_01 N D1 RW byte AVERAGE_TIME_SCALE. Sets the time between two measures. MFR_SPECIFIC_02 Y D2 RW byte DEBUG_MODE. [01/10] Switch [ON/OFF] the Vout control on PMBus domain. MFR_SPECIFIC_05 Y D5 RW byte VOUT_TRIM. Used to apply a fixed offset voltage to the output voltage command value. MFR_SPECIFIC_08 Y D8 RW byte VOUT_DROOP. Used to change the Vout droop. MFR_SPECIFIC_35 N1 F3 RW byte MANUAL_PHASE_SHEDDING. Used to manage the phase shedding manually. MFR_SPECIFIC_38 Y F6 RW byte VOUT_OV_FAULT_LIMIT allows the programming of the OV protection threshold for each rail. MFR_SPECIFIC_39 Y F7 RW byte VFDE_ENABLE. MFR_SPECIFIC_40 Y F8 RW byte ULTRASONIC_ENABLE. MFR_SPECIFIC_41 N1 F9 RW byte GDC_THRESHOLD. To access the internal register to set GDC threshold [A] |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |