51 / 84 page ![]() AD9520-3 Rev. 0 | Page 51 of 84 SERIAL CONTROL PORT The AD9520 serial control port is a flexible, synchronous serial communications port that allows an easy interface with many industry-standard microcontrollers and microprocessors. The AD9520 serial control port is compatible with most synchronous transfer formats, including Philips I2C, Motorola® SPI®, and Intel® SSR protocols. The AD9520 I2C implementation deviates from the classic I2C specification on two specifications, and these deviations are documented in Table 14 of this data sheet. The serial control port allows read/write access to all registers that configure the AD9520. SPI/I²C PORT SELECTION The AD9520 has two serial interfaces, SPI and I2C. Users can select either SPI or I2C depending on the states of the three logic level (high, open, low) input pins, SP1 and SP0. When both SP1 and SP0 are high, the SPI interface is active. Otherwise, I2C is active with eight different I2C slave address (seven bits wide) settings, see Table 40. The four MSBs of the slave address are hardware coded as 1011 and the three LSBs are programmed by SP1 and SP0. Table 40. Serial Port Mode Selection SP1 SP0 Address Low Low I²C, 1011000 Low Open I²C, 1011001 Low High I²C, 1011010 Open Low I²C, 1011011 Open Open I²C, 1011100 Open High I²C, 1011101 High Low I²C, 1011110 High Open I²C, 1011111 High High SPI I²C SERIAL PORT OPERATION The AD9520 I2C port is based on the I2C fast mode standard. The AD9520 supports both I2C protocols: standard mode (100 kHz) and fast mode (400 kHz). The AD9520 I2C port has a 2-wire interface consisting of a serial data line (SDA) and a serial clock line (SCL). In an I2C bus system, the AD9520 is connected to the serial bus (data bus SDA and clock bus SCL) as a slave device, meaning that no clock is generated by the AD9520. The AD9520 uses direct 16-bit (2 bytes) memory addressing instead of traditional 8-bit (1 byte) memory addressing. I2C Bus Characteristics Table 41. I2C Bus Definitions Abbreviation Definition S Start Sr Repeated Start P Stop A Acknowledge A No acknowledge W Write R Read One pulse on the SCL clock line is generated for each data bit transferred. The data on the SDA line must not change during the high period of the clock. The state of the data line can only change when the clock on the SCL line is low. SDA SCL DATA LINE STABLE; DATA VALID CHANGE OF DATA ALLOWED Figure 55. Valid Bit Transfer A start condition is a transition from high to low on the SDA line while SCL is high. The start condition is always generated by the master to initialize the data transfer. A stop condition is a transition from low to high on the SDA line while SCL is high. The stop condition is always generated by the master to end the data transfer. START CONDITION S STOP CONDITION P SDA SCL Figure 56. Start and Stop Conditions A byte on the SDA line is always 8 bits long. An acknowledge bit must follow every byte. Bytes are sent MSB first. The acknowledge bit is the ninth bit attached to any 8-bit data byte. An acknowledge bit is always generated by the receiving device (receiver) to inform the transmitter that the byte has been received. It is done by pulling the SDA line low during the ninth clock pulse after each 8-bit data byte. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |