| データシートサーチシステム |
|
PC87309VLJ データシート(PDF) 14 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87309VLJ データシート(HTML) 14 Page - National Semiconductor (TI) |
|
14 / 192 page ![]() Signal/Pin Connection and Description 14 www.national.com CFG0 92 Configuration Input Group 4 This pin selects between Full-IR and Two-UART mode as the default configuration upon power up. It is pulled down by internal 30 K Ω resistors. External 10 K Ω pull-up resistors to V DD should be employed. This signal is multiplexed with SOUT1. See TABLE 2-1 and Section 2.1. CLKIN 33 Clock Input Group 1 Clock In – A TTL or CMOS compatible 48 MHz clock. CTS2,1 93,83 UART1, UART2 Input Group 1 UART1 and UART2 Clear to Send – When low, these signals indicate that the modem or other data transfer device is ready to exchange data. CTS2 is multiplexed with A11, and available only in Two-UART mode. D7-0 8-1 ISA-Bus I/O Group 5 ISA-Bus Data – Bidirectional data lines to the microprocessor. D0 is the LSB and D7 is the MSB. These signals have 24 mA (sink) buffered outputs. DACK3 DACK2,1 42 39,38 ISA-Bus Input Group 1 DMA Acknowledge 1,2 and 3 – These active low input signals acknowledge a request for DMA services and enable the IOWR and IORD input signals during a DMA transfer. These DMA signals can be mapped to the following logical devices: FDC, UART or Parallel Port. DCD2,1 94,84 UART1, UART2 Input Group 1 UART1 and UART2 Data Carrier Detected – When low, this signal indicates that the modem or other data transfer device has detected the data carrier. DCD2 is multiplexed with P12 and available only in Two-UART mode. DENSEL 97, 48 or 44 FDC Output Group 11 Density Select – Indicates that a high FDC density data rate (500 Kbps or 1 Mbps) or a low density data rate (250 or 300 Kbps) is selected. DENSEL polarity is controlled by bit 5 of the SuperI/O FDC Configuration register as described in Section 2.5.1. This signal is multiplexed with: IRTX, , DR1, or R12. DIR 50 FDC Output Group 11 Direction – This output signal determines the direction of the Floppy Disk Drive (FDD) head movement (active = step in, inactive = step out) during a seek operation. During reads or writes, DIR is inactive. DR1,0 48, 47 FDC Output Group 11 Drive Select 0 and 1 – These active low output signals are the decoded drive select output signals. DR0 and DR1 are controlled by Digital Output Register (DOR) bits 0 and 1. They are encoded with information to control four FDDs when bit 7 of the SuperI/O FDC Configuration register is 1, as described in Section 2.5.1. DR0 can optionally become a logical OR of DR0 and MTR0 when MTR0/DRATE0 is used as DRATE0. DR1 is multiplexed with DENSEL and is available only in Two-UART mode. Optionally, it can become a logical OR of DR1 and MTR1 when MTR1/P12 is used as P12. See MTR0,1 for more information. DRATE0 95, 45 or 43 FDC Output Group 14 Data Rate 0 – This output signal reflects the value of bit 0 of the Configuration Control Register (CCR) or the Data Rate Select Register (DSR), whichever was written to last. Output from the pin is totem-pole buffered (6 mA sink, 6 mA source). This signal is multiplexed with IRRX1/P12, MTR0 or DSR2 DRQ3-1 37-35 ISA-Bus Output Group 13 DMA Request 1, 2 and 3 – These active high output signals inform the DMA controller that a data transfer is needed. These DMA signals can be mapped to the following logical devices: Floppy Disk Controller (FDC), UART or parallel port. DSKCHG 58 FDC Input Group 1 Disk Change – This input signal indicates whether or not the drive door has been opened. The state of this pin is available from the Digital Input Register (DIR). This pin can also be configured as the RGATE data separator diagnostic input signal via the MODE command. See the MODE command in Section 3.7.7. Signal/Pin Name Pin Number Module I/O and Group # Function |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |