64 / 146 page ![]() 3.13 Temperature warning and thermal shutdown Figure 25. Thermal shutdown protection and diagnosis Active Mode Standby Modes (during cyclic sense ) Temperature Warning Diagnosis: TW = 1 TSD1 All outputs and V2: off V1 remains on Diagnosis: TSD1 = 1 TJ > TSD1 TSD2 All outputs: off V1,V2: off for 1.5 sec(typ) Diagnosis: TSD2 = 1 TJ > TSD2 Forced Vbatstby 7x TSD2 within one minute Wake-up event Power-on reset event 'Read and Clear' and TJ < TW TJ > Tw T= 1.5sec(typ) Power-on Reset All outputs incl V1 off Vs > Vpor 'Read and Clear' and TJ < TSD1 Note: The thermal state machine recovers the same state where it was before entering standby mode. In case of a TSD2 it is entered in TSD1 state. L99DZ320 Functional description DS14235 - Rev 5 page 64/146 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|