Back Button H8SX/1663R Datasheet HTML 140Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 141Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 142Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 143Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 144Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 145Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 146Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 147Page - Renesas Technology Corp H8SX/1663R Datasheet HTML 148Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 144 / 1504 page
background image
Section 5 Voltage Detection Circuit (LVD)
Rev. 2.00 Sep. 24, 2008 Page 112 of 1468
REJ09B0412-0200
5.3.3
Release from Deep Software Standby Mode by the Voltage-Detection Circuit
If the LVDE and LVDRI bits in LVDCR and the DLVDIE bit in DPSIER have all been set to 1
during a period in deep software standby mode, the voltage-detection circuit requests release from
deep software standby mode when Vcc falls to or below Vdet. This sets the DLVDIF bit in
DPSIFR to 1, thus producing release from the deep software standby mode. For the deep software
standby mode, see section 28, Power-Down Modes.
5.3.4
Voltage Monitor
The result of voltage detection by the voltage-detection circuit can be monitored by checking the
value of the LVDMON bit in LVDCR. When the LVDMON bit has been enabled by setting the
LVDE bit, 0 indicates that Vcc is at or below Vdet and 1 indicates that Vcc is above Vdet. This
bit should be read while the voltage-monitoring reset has been disabled by setting the LVDRI bit
to 1.
Before clearing the LVDF bit in RSTSR to 0, confirm that the LVDMON bit is set to 1 (indicating
that Vcc is above Vdet). When it is impossible to clear the LVDF bit despite the LVDMON bit
being 1, the voltage-detection circuit is in the state of waiting for stabilization. In such cases, clear
the bit again after the stabilization time (t
por) has elapsed.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com